ENDRESS(Liquiphant M - FTL50(H) / FTL51(H))


Description

Built-in amplifier, liquid absorbing paper not needed,usable with various liquids..


Product Information
    Benefits
    • Use in safety systems requiring functional safety to SIL2/SIL3 in accordance with IEC 61508/IEC 61511-1
    • International explosion protection certificates and overfill prevention certificate (WHG)
    • No calibration required, easy to start up
    • No mechanically moving parts: no maintenance, no wear, long operating life.
      Monitoring of fork for damage: guaranteed function
    • Second line of defense to protect the environmental
    • Variety of standardized process connections for all applications
    • Stainless steel (316L) and high-corrosion resistant sensor material (Alloy)
    Field of application
    Point level switch for all liquids.
    • Process connections: Threads, flanges and hygienic process connection (Tri-Clamp)
    • Temperature: -50 to +150°C (-58 to +302°F)
    • Pressure: -1 to +64bar (-14.5 to +928psi)
    • Sensor material: 316L, Alloy
    • International explosion protection certificates, overfill prevention WHG, SIL, marine approvals
    Features and specifications
    Measuring Principle Vibration Liquids
    Characteristic / Application Liquiphant M Density with Density Computer FML621 Temperature and Pressuremeasurement
    Modular housing concept wide range of process connections
    compact
    for compensation (option)
    Supply / Communication Transmitter power supply (MUS)
    Ambient temperature -50...70°C
    -50...60°C for hazardous applications
    Process temperature 0...80°C (validity of accuracy data)
    -50...0°C /80...150°C (with reduced technical data)
    Process pressure absolute 0...25bar
    >25...64bar (with reduced technical data)
    Wetted parts 316L/C4
    Sensor length Compact: 50,5mm
    Output Pulse
    Certificates / Approvals ATEX
    IECEx
    Specialities Commissioning with ReadWin2000
    Components Density Computer FML621
    Other approvals and certificates SIL2/ SIL3
    Measuring Principle Vibration Liquids
    Characteristic / Application Modular housing concept
    wide range of process connections
    Analogue and bus interfaces
    Extensive certificate range (e.g. Ex,WHG)
    compact, e.g. pipes
    Specialities Foamdetection
    Detekt a densitychange
    second line of defense
    Supply / Communication PROFIBUS PA
    19...253V AC
    10...55V DC-PNP
    19...253V AC or 10...55V DC
    8/16mA, 11...36V DC
    NAMUR
    PFM
    Ambient temperature -50 °C...+70 °C
    (-58 °F...+158 °F)
    Process temperature -50 °C...+150 °C
    (-58 °F...+302 °F)
    Process pressure absolute / max. overpressure limit Vacuum...64 bar
    (Vacuum...928 psi)
    Min. density of medium 0.5g/cm³(0.4g/cm³ option)
    Main wetted parts 316L, Alloy
    Process connection Thread:
    G3/4A, G1A, R3/4", R1, NPT3/4, NPT1
    Flange:
    DN25...DN100,
    ASME 1"...4",
    JIS 25A...100A
    Process connection hygienic Tri-Clamp ISO2852
    Communication PROFIBUS PA
    19...253V AC
    10...55V DC-PNP
    19...253V AC or 10...55V DC
    8/16mA, 11...36V DC
    NAMUR
    PFM
    Certificates / Approvals ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
    Safety approvals Overfill prevention WHG
    SIL2/ SIL3
    Design approvals EN 10204-3.1
    NACE MR0175, MR0103
    ASME B31.3
    AD2000
    Marine approval GL/ ABS
    Options Heavy duty stainless steel housing mainly for the oil and gas industry
    Components FTL325P/FTL375P Interface PFM
    FTL325N/FTL375N Interface NAMUR

Related Products